Your Reliable Liquid Nitrogen Supply

Home / All /

Biobank Container

Biobank Container

Scala Stainless Steel Liquid Nitrogen Biological Container, Automatic, Safe and Reliable Cryogenic Storage Experience

Advanced manufacturing technologies, highly compatiable, easy operation, automatic, safe and reliable cryogenic storage experience
-190℃ preservation, maximum storage capacity, auto temperature monitoring, automatic filling liquid nitrogen, minimal LN2 consumption
Bio-sample container

Overview

Biological Container

Scala Intelligent Liquid Nitrogen Biological Container


· -190℃ preservation
· Automatic filling liquid nitrogen
· Temperature and liquid monitor
· Intelligenet control
· Gas bypass

· LN2 Capacity: 90L; 200L; 340L; 375L; 455L; 552L; 870L; 1616L; 1837L
· Neck Opening: 318mm; 406mm; 445mm; 610mm; 635mm; 787mm; 1103mm

Biological Container_1
Biological Container_2
Biological Container_3
LCD_screen
SCALA brand liquid nitrogen biological containers, made of high quality austenitic stainless steel, provide users with automatic, safe and reliable cryogenic storage experience. Equipped with casters and brakes, and wide neck opening for easy store and pick, the containers are ideal equipment for long-term cryogenic storage of high value items such as stem cells, embryos, sperm and biological products. Adopted with high vacuum multi-layer insulation technology and structure, temperature differences do not exceed 10℃, and lowest temperature can reach -190℃, the containers can keep lowest liquid nitrogen consumption rate while maintain maximum storage capacity. The intelligent monitoring system of the containers are compatible to the needs of various scenarios, with auto fill of liquid nitrogen, real-time monitoring of liquid level, high and low point temperature, multi-directional alarm system, etc. The monitoring signal can also be transmitted to the central computer unified monitoring and control so that you can obtain the operation information of the equipment any time.

Features

Intelligent Management

Automatic liquid nitrogen refill/stop, liquid nitrogen level monitor, temperature monitor of the top, bottom and hot gas bypass, LCD screen display

CE Certification

Workmanship manufacturing with advanced technologies, high vacuum, special insulation material and trusted supplier; safety and reliability commitment

Operation Friendly

Automatic demisting, wide opening for easy access and storage, casters and brakes for easy mobility, folding steps for female operators, humanized designs

Temperature Uniformity

High standard insulation material to maintain excellent temperature control, minimal temperature differences, less temperature vibration while opening the lid

Longer Duration

Longest 158 days duration with full liquid nitrogen, over 25 years service lifespan, -190℃ at top,  -150℃ within 48 hours even when the lid open for a long time

Minimum LN2 Loss

Hot gas bypass avoids temperature fluctuations inside the container, ensure sample in good condition and reduce unnecessary liquid nitrogen loss

Applications

Biological Bank

Biological Bank

Animal Husbandary
Animal Husbandary

Cryopreservation
Cryopreservation

Medical Center
Medical Center

Models

1 products found
ViewListShowcase

Advantages

· High quality commitment, CE and MEDICAL DEVICES QUALITY certified
  Our products are manufactured via highly automated manufacturing lines with advanced technologies, laser cut, robot welding, high vacuum, special insulation material and trusted austenitic stainless steel supplier.
· Excellent temperature uniformity and stability
  Our bio-containers adopted to high standard insulation material to maintain excellent temperature control, offset neck container temperature differences are within 10℃ and top temperature can be as low as 190℃.
· Maximum storage capacity
  Compared with other brands, our bio-containers occupy less space and could store more samples; save space and reduce cost.
· Automatic and safe LN2 refilling
  Equiped with auto LN2 refilling system, users can set specific factors and LN2 will be refilled automatically once the liquid level reaches to the lower level based on the differential pressure sensor. 
· Hot gas bypass to reduce liquid nitrogen loss
  The bypass is designed to remove hot nitrogen gas before the refill of liquid nitrogen; this avoid temperature fluctuations inside the container, ensure sample in good condition and reduce unnecessary liquid nitrogen loss.
· Intelligent control system with compatible moulding units
  Our bio-containers are controlled by intelligent system with flexiable moulding units, users can expand control units to meet special requirements.
· Accurate temperature control
  Our products have 3 platinum resistance temperature probes which can test minor temperature change, accuracy of ±1℃; temperature of the top, bottom, liquid level, and operating status can be read via LCD screen.
· Customized alarms for temperature, liquid level, power connection
  Users can set specific conditions on alarms on temperature, liquid level, power connection and LN2 refill; messages will display on LCD screen.
· User friendly and other humanized designs
  Automatic demisting, auto filling, wide opening for easy access and storage, casters and brakes for easy mobility, folding steps for female operators, and many other humanized designs to make more convenience.
· Best service commitment
  SCALA has senior product experts and sevice team to ensure our products meet your requirement; our powerful supply chain ensures timely delivery and superb quality ensurance.

Specifications

Offset Neck Models
Model
YDD-375-318P
YDD-418-318P
YDD-870-455P
YDD-1616-635P
YDD-1837-635P
Opening Diameter (mm)
318
318
455
636
636
Usable Internal Height (mm)
708
888
855
780
900
Internal Diameter (mm)
755
755
1,042
1,460
1,460
External Height (mm)
1,245
1,425
1,540
1,590
1,720
External Diameter (mm)
813
813
1,120
1,535
1,535
Weight Empty Load (kg)
255
280
470
780
810
Weight Full LN2 Load (kg)
550
640
710
1,420
1,520
Total Volumn of LN2 (L)
375
418
870
1,616
1,837
Platform Vapor Storage LN2 Capacity (L)
55
55
135
300
320
Storage
Capacity of 
Cryogenic
Vials
1.2/2ml cryo vials
15,600
19,500
42,000
81,900
94,500
Racks (100 cell boxes)
12
12
26
60
60
Racks (25 cell boxes)
4
4
16
12
12
Racks Layers
12
15
14
13
15
Storage
Capacity of
Blood
Bags
25ml (rack/layer/bag)
204/6/1,224
204/9/1,836
398/8/3,184
804/7/5,628
804/8/6,432
50ml (rack/layer/bag)
128/6/768
128/8/1,024
241/7/1,687
490/6/2,940
490/8/3,920
250ml (rack/layer/bag)
104/4/416
104/5/520
192/4/768
402/4/1,608
402/5/2,010
500ml (rack/layer/bag)
76/4/304
76/5/380
144/4/576
310/4/1,240
310/5/1,550
Performance
Duration with Full LN2 (Days)
79
65
80
135
158
Duration under Full LN2 (Days)
11
8
11
24
26
Temperature on Top (℃)
-190
-190
-190
-190
-190
Wide Neck Models
Model
YDD-90-406
YDD-200-610
YDD-340-787
YDD-552-1103
Opening Diameter (mm)
406
610
787
1,103
Internal Diameter (mm)
406
610
787
1,103
External Height (mm)
1,041
1,041
1,041
1,194
Total Volumn of LN2 (L)
90
200
340
1,103
Weight Empty Load (kg)
97
147
189
372
Weight Full LN2 Load (kg)
161
309
463
735
Storage
Capacity of 
Cryogenic
Vials
1.2/2ml cryo vials (liquid)
5,200
13,500
22,100
37,700
1.2/2ml cryo vials (gas)
4,400
11,000
18,700
31,900
Racks (100 cell boxes)
4
10
17
29
Racks Layers (liquid)
13
13
13
13
Racks Layers (gas)
11
11
11
11
Storage
Capacity of
Blood
Bags
25ml (rack/layer/bag)
50/7/350
125/7/875
225/7/1,575
375/7/2,625
50ml (rack/layer/bag)
34/7/238
90/7/630
154/7/1,078
256/7/1,792
250ml (rack/layer/bag)
28/4/112
64/4/256
112/4/448
174/4/696
500ml (rack/layer/bag)
22/4/88
50/4/200
82/4/328
152/4/608
Performance
Duration with Full LN2 (Days)
30
40
48
62
Evaporation Rate (L/Day)
3
5
7
9
Temperature on Top (℃)
-135
-135
-135
-135
Quick Quotation
Scala can provide liquid nitrogen generators for research institutions, laboratories, health care centers, universities and Scala brand dealers, etc.
  • Quick Quotation
    • *Email
      Tel